Indispensable for anyone who, along with a circular saw, planer, belt grinder, or piercing saw, would also like to operate a vacuum device, vacuum cleaner, etc. without surge overloading the fuse. With the work machine switched on, the second appliance switches itself on automatically after two to three seconds. This prevents in-house fuse overloading. As required by the hazardous material ordinance, the vacuum device runs for three to four seconds extracting the rest of the dust after the work machine is switched off.
The start time delayer does not limit the consumer's starting current.
Technical data
Line data: | 3 / N / PE, 400V / 230V / 50Hz |
Connection power total: | min. 100W (threshold), max. 400V / 16A / 11000W |
Sockets delayed Rated breaking capacity AC-1: Rated breaking capacity AC-3: |
230V / 400V / 16A 230V / 13.5A / 3kW or 400V / 9A / 4kW |
Network input: | Plug-collar CEE 5-pole, 3P+N+E, 16A, 6h with phase inverter |
Outgoing Master: Slave (delayed): |
1 socket CEE 5-pole, 3P+N+E, 16A, 6h + 1 socket Schuko 2P+E, 16A 1 socket CEE 5-pole, 3P+N+E, 16A, 6h + 1 socket Schuko 2P+E, 16A |
Degree of protection: | IP 44 |
Fixation enclosure: | 4 bushes M5 - 68 x 68mm at the bottom of the enclosure |
Material / colour: | ABS / enclosure grey, PA / plug collar and CEE-sockets red, Schuko sockets black |
Dimensions (LxWxH): | 245 x 123 x 153mm |
Weight: | ca. 1250g |