- Braking current potentiometer
- Braking time potentiometer
- R-Contact / Discharge resistor
- Function: analog controlled DC braking
- Actuation type: electrically via control contact SP
Technical data
Rated operational voltage Ue: | 230V +-15% / 50-60Hz (195…264V) |
Braking current at 50 Hz I: at 60 Hz I: Adjustment: |
max. 15A max. 12A stepless via control potentiometer I max |
Braking time t: Adjustment: Setting value: |
ca. 1 – 12s stepless via control potentiometer t max ca. 12s |
Device fuse: | F 16A |
Controll: | analog / phase angle |
Ambient temperature: | 0 – +40°C |
Storage temperature: | -20 – +70°C |
Degree of pollution: | 2 |
Switching cycles: | max. 1/min |
Power input: | 2 flat pin connection 6,3 x 0,8mm / Label: I / L2 |
Control input: | 1 flat pin connection 6,3 x 0,8mm / Label: SP |
Brake outgoing: | 2 flat pin connection 6,3 x 0,8mm / Label: V2 / C1 |
Signal contact: | 1 flat pin connection 6,3 x 0,8mm / Label: 5 |
Degree of protection: | IP 00 |
Version: | Printed circuit board version |
Fixation: | 4 drill holes Ø 3,2mm – 67 x 45mm |
Dimensions L x W x H: | ca. 75 x 53 x 22mm |
Weight: | ca. 40g |
Conformity: | CE |
Tests: | EMV |
Safety category: | 1 |
Performance Level (PL): | c |